Helena Actalyke & MAX-ACT
The Actalyke Activated Clotting Time test system takes a bold step forward in the management of heparin anticoagulation. Actalyke analyzers are for use at the point of care during cardiopulmonary bypass, cardiac catheterization, angioplasty, hemodialysis and other procedures where heparin monitoring with accurate ACT results is needed. For enhanced user flexibility and cost-effectiveness. Actalyke instruments and test tubes are interchangeable with other ACT systems using electromagnetic clot detection principles.

Actalyke XL
Accurate Activated Clotting Time (ACT) testing is essential for monitoring heparin therapy during cardiac procedures and dialysis. Actalyke instruments and reagent tubes provide the sensitivity, reliability and rapidity needed to make timely treatment decisions at the point of care.
All Actalyke instruments use a two-point clot detection mechanism, enabling clot detection at the early fibrin formation stage with less variation due to clot fragility. This provides greater precision, especially on highly heparinized and diluted samples. The Actalyke XL is a premier analyzer offering dual-well testing, excellent reproducibility and strong data handling features. The XL is fully compatible with all ACT tubes. Helena offers a full line of Actalyke ACT tubes, including traditional glass bead, kaolin, celite® plus new MAX-ACT.
| Cat. No. | Item |
| 5770 | Actalyke XL Analyzer, 110/220V |
| 9133 | Service Manual for Actalyke XL |
| 1199 | Replacement Agreement for XL Analyzer |
Actalyke XL Specifications
Tests: Whole Blood Activated Clotting Time (ACT). Accepts Actalyke ACT Tubes with celite, kaolin, glass-bead activators; MAX-ACT Tubes with blended activators; all International Technidyne Hemochron® tubes
Measurement Range: 0-1500 seconds
Incubation Temperature: 36.5ºC - 37.5ºC (97.7ºF - 99.5ºF)
Dimensions: 10.7”W x 8.0”H. x 12.0”L (27.2 x 20.3 x 30.5 cm)
Display: 3.2” x 4” Color LCD Touch Screen (8.1 x 10.2 cm)
Weight (with printer): 15 lbs. (6.8 kg)
Line Voltage: 47-63 Hz, 85-265 V A/C
Battery: Rechargeable
Environment: 15ºC to 30ºC (59 to 86ºF)
Data Input: LCD touch screen; Optional bar code reader for patient ID entry
Data transfer capability: 3.5” Diskette, RS232, RF Transmit, Printer
CLIA Classification: Moderately Complex
CE Certified; NCCLS-POCT 1-A Compliant
Actalyke Electronic Clotting Tube
| Cat. No. | Item |
| XL-ECT | Actalyke Electronic Clotting Tube, 1/pkg |
The Electronic Clotting Tube is a single device which simulates patient sample clots at three therapeutic heparin levels: 100 seconds (Level I Normal), 300 seconds (Level II Abnormal) and 500 second (Level III Abnormal) for daily quality control of all Actalyke instruments. To ensure consistent and proper instrument operation, this check should be performed once per shift on any shift in which the analyzer is used. The Electronic Clotting Tube features a flashing status indicator when activated as well as low battery indicator.
Actalyke XL Accessories and Supplies
| Cat. No. | Item |
| 5757 | Actalyke Thermometer |
| 5758 | Actalyke XL Barcode Reader and Cable |
| 5759 | Actalyke XL Battery Pack |
| A-PPR | Actalyke Thermal Printer Paper (3 rolls) |
| XL-ECT | Actalyke Electronic Clotting Tube |
Actalyke MINI II
Activated Clotting Time (ACT) Analyzer
The MINI II is the simplest, least expensive ACT instrument available, yet it retains high sensitivity, 2-point clot detection for greatest reliability. Performance, linearity and CVs parallel larger Actalyke analyzers. It’s ideal for use in the catheterization, dialysis or the surgical suite. Optional battery pack available.
6” Footprint - The MINI II features a very small footprint, but has a very large high visibility screen. Operation of the MINI II is extremely simple. Just insert the ACT reagent tube containing whole blood and push the button.
Full Cross-Compatibility - The MINI II is fully compatible with all ACT tubes. Helena offers a full line of Actalyke ACT tubes, including traditional glass bead, kaolin and celite, plus new MAX-ACT.
| Cat. No. | Item |
| 5753 | Actalyke MINI II Analyzer, 110/220V (w/printer) |
| 5755 | Actalyke MINI II Analyzer, 110/220V (without printer) |
| 5763 | Actalyke MINI II, 110/220V (with printer and battery) |
| 5765 | Actalyke MINI II, 110/220V (with battery) |
| 1197 | Comprehensive Replacement for Actalyke MINI II Analyzer |
| 9134 | Service Manual for Actalyke MINI II |
Actalyke MINI II Specifications
Tests: Whole Blood Activated Clotting Time (ACT). Accepts Actalyke ACT Tubes with celite, kaolin, glass-bead activators; MAX-ACT Tubes with blended activators; all International Technidyne Hemochron® tubes
Measurement Range: 0-1500 seconds
Incubation Temperature: 36.5ºC - 37.5ºC (97.7ºF - 99.5ºF)
Dimensions: 6.1”W x 4.8”H x 6.3”L (15.5 x 12.2 x 16.0 cm)
Display: 3.2 x 1" (8 x 2.54 cm)
Weight (with printer): 5.3 lbs. (2.4 kg) (with battery):
Line Voltage: 47-63 Hz, 85-265 V A/C (Battery optional - DC)
Environment: 15ºC to 30ºC (59 to 86ºF)
Data Transfer Capability: Printer option available for hard copy
CLIA Classification: Non-waived
Actalyke MINI II and MINI Accessories and Supplies
| Cat. No. | Item |
| 5754 | Actalyke MINI II Battery Pack |
| 5757 | Actalyke Thermometer |
| A-PPR | Actalyke Thermal Printer Paper (3 rolls) |
| XL-ECT | Actalyke Electronic Clotting Tube |
| 9132 | Service Manual Actalyke MINI |
MAX-ACT™ Tubes
| Cat. No. | Item |
| MAX-ACT | MAX-ACT Tubes (Gray Flip-Top), 50 tubes/box |
MAX-ACT Tubes, with an upper linearity limit of 6 units of heparin per mL of blood, are ideal for monitoring patients receiving moderate to high heparin dosages. For maximum heparin specificity, MAX-ACT contains multiple particulate activators - kaolin, celite, and glass beads - that ensure maximal Factor XII activation and compensate for potential patient sensitivity to a single activator. To perform test, simply add 0.5 cc of whole blood to the MAX-ACT tube, mix and insert into the Actalyke. Results are displayed in seconds. Store tubes at room temperature.
Celite Tubes
| Cat. No. | Item |
| C-ACT | Celite ACT Tubes (Black Flip-Top), 50 tubes/box |
C-ACT Tubes contain a celite (diatomaceous earth) activator and can be used to monitor patients undergoing procedures requiring administration of moderate to high heparin concentrations. Perform testing by adding 2.0 cc of whole blood to the tube, mix, and insert tube into the Actalyke. Store Celite ACT tubes at room temperature.
Kaolin ACT Tubes
| Cat. No. | Item |
| K-ACT | Kaolin ACT Tubes (Yellow Flip-Top), 50 tubes/box |
Kaolin ACT Tubes are useful in monitoring patients receiving moderate to high heparin concentrations, in the presence of anti-fibrinolytics. Testing requires adding 2.0 cc of whole blood to the tube, mix, and insert tube into the Actalyke. Store tubes at room temperature.
Glass Bead ACT Tubes
| Cat. No. | Item |
| G-ACT | Glass Bead ACT Tubes (White Flip-Top), 50 tubes/box |
The Glass Bead ACT is useful for monitoring patients undergoing procedures requiring low to moderate heparin dosages. Perform testing by simply adding 0.4 cc of whole blood to the tube, mix, and insert tube into the Actalyke. Store G-ACT tubes at room temperature.
AQC-HP Control Kit for MAX-ACT, C-ACT, K-ACT
| Cat. No. | Item |
| AQC-HP | QC Kit 1 Normal, 1 High Control |
| 10 x 1 mL QC Level - I | |
| 10 x 1 mL QC Level - III | |
| 2 x 10 mL Diluent | |
| 2 x 10 mL Calcium Chloride |
The QC Kit is for use in verifying reagent performance with MAX-ACT, C-ACT and K-ACT Tubes. The kit provides two levels of quality control, normal and high. The lyophilized control is stable one hour at room temperature once reconstituted.
AQC-LP Control Kit for G-ACT
| Cat. No. | Item |
| AQC-LP | G-ACT QC Kit 1 Normal, 1 Low Control |
| 10 x 1 mL QC Level - I | |
| 10 x 1 mL QC Level - II | |
| 2 x 10 mL Diluent | |
| 2 x 10 mL Calcium Chloride |
The G-ACT QC Kit is for use in verifying reagent performance with Glass Bead ACT (G-ACT) Tubes. The kit provides two levels of quality control, normal and low. The lyophilized control is stable one hour at room temperature once reconstituted.